The EEA-PAM-561-E-32 power amplifier card is manufactured by Vickers within the EEA-PAM Power Amplifiers series. Designed for closed-loop hydraulic motion control, the board accepts machine-level reference signals, conditions them, and drives proportional valve coils to regulate pressure or flow in automated equipment. It mounts in a 32-way Eurocard rack and uses the series edge connector for installation in compatible control assemblies. By combining alarm, monitoring, and sensor interfaces on a single printed circuit assembly, the module reduces panel wiring and supports straightforward system setup.

Nominal operation requires a supply of 24 VDC, while an auxiliary rail provides +15 VDC for external transducers. The edge interface follows the DIN 41612 back-plane standard, and the pin arrangement uses the F48 pattern so the card seats correctly in compatible Eurocard enclosures. For feedback devices, the sensor channel can accept currents up to 20 mA and voltages up to 24 V, while input resistances of 100 ? for current and 100 k? for voltage help protect the conditioning stages from excess load. A monitor jack tied through 10 k? allows command signals to be checked without opening the circuit, and the opto-switch input is isolated by 2.7 k? to limit current drawn from the control electronics.

Status circuitry includes an out-of-range output that can source up to 100 mA from the system 24 V rail, along with a separate alarm line rated for 50 mA. The enable input has a high impedance of 47 k?, which helps prevent unnecessary loading of interlock and safety circuits. The board also provides a 2 mm test jack for oscilloscope probes during dynamic tuning. These current-limited outputs and high-impedance inputs help keep analog control signals isolated from switching noise during valve operation.

Technical Specifications

Alarm Output Max Current
50 mA
Alarm Output Resistance
50 ?
Control Supply Output
+15 VDC
Control Voltage
10.5 to 30 V DC
Current Consumption
Max 2.5 A
Current Inputs
~15V, ~10V with specific maximum current ratings
Edge Connector Standard
DIN 41612
Edge Connector Type
F48
Enable Input Resistance
47 k?
Housing Type
Plug-in unit of 3U height (IEC 297)
Input Voltage
24 V DC
Max Sensor Current Input
20 mA
Max Sensor Voltage Input
24 V
Monitor Jack Resistance
10 k?
Mounting Type
Plug-in Card (Eurocard)
Nominal Supply Voltage
24 VDC
Nominal Voltage
24V DC, 50W
Opto Switch Input Resistance
2.7 k?
Out-of-range Output Max Current
100 mA
Out-of-range Output Nominal
24 VDC
Output Current
Max 2 A
Sensor Current Input Resistance
100 ?
Sensor Voltage Input Resistance
100 k?
Shut-down
Below 18V DC, Reverse-polarity protection
Signal Inputs
Voltage / Current (configurable)
Size (l X W X H)
Approx. 254 mm x 100 mm x 40 mm
Solenoid Current
Max. 3.2A
Test Jack Diameter
2 mm
Voltage Range
20V to 40V (including pk-to-pk ripple up to 10%)
Weight
330g (0.15 lb)

Click here for product datasheet

Contact Us

1620 Old Apex Road, Cary, NC 27513, USA

Toll Free: 1-888-551-3082

International: 1-919-443-0207

Fax: 1-919-867-6204

Email: sales@wakeindustrial.com

Shipping Options

DHL FedEx UPS Freight

Payment Methods

American Express MasterCard Visa Wire Transfer

Need Assistance?

Our team is here to help you find the right part for your needs.

Shipping logo

Worldwide Shipping with FedEx and UPS.

Payment logo

We accept all major credit cards

Warranty logo

1 year Automation Factory warranty on ALL products