The EEA-PAM-525-E-32 is a plug-in power amplifier card produced by Vickers for closed-loop hydraulic motion tasks in industrial automation. It belongs to the EEA-PAM Power Amplifiers series and shapes command and feedback currents so proportional valves can follow electronic control signals without oscillation. This type of card is used where analog command shaping and stable valve response are needed for cylinders, presses, or positioning axes. The module occupies a single rack slot and provides separate terminals for command inputs, sensor feedback, and status outputs that connect directly to a PLC or other machine controller.

The board draws its logic and coil power from a backplane supply rated at 24 V DC and 50 W. That arrangement lets the card support both control logic and valve actuation from the same rack supply. Command lines accept a discrete level of 24 V DC and use an input impedance of 2.7 k?, while a separate enable line is buffered by 47 k? to reduce the chance of unintended activation. Three operating modes are selected by a rotary switch with 3 fixed detents for quick setup, and internal reference rails provide +15 V DC for external potentiometers or position transducers. A monitor point routes real-time valve current through a 10 k? series resistor, and its 2.0 mm socket supports safe probe connection during service checks.

Process sensors connect on separate feedback paths. Current feedback is limited to 20 mA through a 100 ? shunt, while voltage feedback is accepted up to +24 V through a 100 k? divider to keep loading low on the source device. Keeping the sensing channels separated helps the card work with different transducer types without cross-loading the input stages. Separate alarm and out-of-range outputs are available for relays, lamps, or digital inputs, so the controller can distinguish normal operation from a detected fault. Status signaling remains clear without adding unnecessary load to the connected feedback circuits.

Technical Specifications

Alarm Output Max Current
50 mA
Alarm Output Resistance
50 ?
Control Supply Output Voltage
+15 V DC
Current Output
~50 mA
Digital Input Nominal Voltage
24 V DC
Digital Input Resistance
2.7 k?
Dimensions
50 mm (W) x 270 mm (D) x 180 mm (H)
Enable Input Resistance
47 k?
Feedback Type
LVDT
Input Impedance (voltage)
~47k?
Input Signal
~10 V or 4...20 mA
Input Voltage
24 VDC
Mode Switch Positions
3
Monitor Point Output Resistance
10 k?
Monitor Point Socket Diameter
2.0 mm
Mounting
DIN rail or rack
Out-of-range Output Max Current
100 mA
Out-of-range Output Nominal
24 V DC
Output Voltage For Valve
~15 V
Power Consumption
Max 18 VA
Power Supply Nominal
24 V DC x 50 W
Protection Class
IP20
Ramp Function
Switchable, 50ms-5s
Sensor Current Input Max
20 mA
Sensor Current Input Resistance
100 ?
Sensor Voltage Input Max
+24 V
Sensor Voltage Input Resistance
100 k?
Signal Connector
Screw terminals
Temperature Range
0...+50 degrees C (operating)
Type
Servo Amplifier
Weight
Approx. 1.2 kg

Click here for product datasheet

Contact Us

1620 Old Apex Road, Cary, NC 27513, USA

Toll Free: 1-888-551-3082

International: 1-919-443-0207

Fax: 1-919-867-6204

Email: sales@wakeindustrial.com

Shipping Options

DHL FedEx UPS Freight

Payment Methods

American Express MasterCard Visa Wire Transfer

Need Assistance?

Our team is here to help you find the right part for your needs.

Shipping logo

Worldwide Shipping with FedEx and UPS.

Payment logo

We accept all major credit cards

Warranty logo

1 year Automation Factory warranty on ALL products