Technical Specifications
Built-in Regenerative Resistor
Duct cooling section; adjustable for external use
Control Circuit Input Power
Single-phase 200-230 VAC +10%/-15%, 50/60 Hz ±3 Hz
Control Functions
Velocity, torque, or position control
Dynamic Brake
Built-in emergency stop; alarm-activated
Heat Dissipation (duct cooling part)
37 W
Heat Dissipation (mounting part)
58 W
Leakage Current
Max. 3.0 mA
Main Circuit Input Power
3-phase 200-230 VAC +10%/-15%, 50/60 Hz ±3 Hz
Manchester Coding Transfer
25 µs typ; cycle 42 µs ±2 µs
Manchester Coding Transmission System
2 Mbps, 2x25-bit frames, 3-bit CRC
Operating Temperature
0°C to 55°C (32°F to 131°F)
Operating/Storage Humidity
Max. 90% RH (no condensation)
Storage Temperature
-20°C to 65°C (-4°F to 149°F)
Total Heat Dissipation
95 W
Vibration Resistance
0.5 G, 10-55 Hz, 2 h on X, Y, Z axes