BL-D75A by Okuma
Get a Quote for BL-D75A
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
The Okuma BL-D75A is an axis drive unit in the BL Servo Drives series produced by Okuma. Designed to regulate the torque, speed, and position of a single servo axis, the device interfaces directly with Okuma machine tools and other automation cells. It receives reference commands, modulates motor current, and supplies real-time status signals so the host controller can maintain precise closed-loop motion. This control arrangement allows the connected axis to respond accurately to changing motion commands and operating loads.
Compatibility with 5020 and 7000 controls means the drive accepts command words and feedback protocols native to these Okuma CNC platforms. If the DC bus voltage falls below 200 VDC, the low-voltage trip circuit disconnects the output stage to protect the semiconductors from undervoltage saturation. The unit issues an overcurrent alarm whenever motor demand exceeds 120% of the current limit, preventing bond-wire damage during stalls. If the control supply collapses, VR-LOSS monitoring detects the dropout and initiates an orderly stop. The internal dynamic brake converts kinetic energy into heat through the resistor network rather than allowing uncontrolled motion.
Ground fault protection is provided by a high-speed no-fuse breaker that interrupts fault current before it can energize the machine frame. Thermal stability of the power stack is maintained by FOL overheat detection, which responds when the monitored section reaches an excessive temperature. The regenerative circuit has a separate OH overheat detection sensor to reduce the risk of resistor damage during rapid deceleration. During prolonged heavy loads, an armature-winding thermostat opens the control loop when the coil temperature reaches its preset threshold. The axis remains stopped while the winding cools, preventing continued current flow from increasing the thermal load. These independent protective circuits respond to electrical faults, supply loss, and excessive heat at the affected section of the drive.
Technical Specifications
Control Compatibility
5020 And 7000 Controls
Control Power Protection
VR-LOSS Monitoring
Grounding Protection
High-Speed No-Fuse Breaker
Heat Sink Protection
FOL Overheat Detection
Lv Trip Threshold
<200 VDC
Overcurrent Threshold
>120% Of Current Limit
Overload Sensor
Armature-Winding Thermostat
Regen Protection
OH Overheat Detection
Stop Method On Alarm
Dynamic Brake
Unit Type
Axis Drive Unit
Contact Us
1620 Old Apex Road, Cary, NC 27513, USA
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Fax: 1-919-867-6204
Email: sales@wakeindustrial.com
Need Assistance?
Our team is here to help you find the right part for your needs.