Technical Specifications
Analog Output
~10 V, 12-bit, 4.9 mV sensitivity
Continuous Current (Amps)
1.2 (1?), 1.2 (3?) A at 115V
Digital Output
0-48 V, 60 mA max, open collector
Fault Contact Closing Time
Close ? 3 ms, Open ? 2 ms
Line Frequency
47-63 Hz
Line Fuses
FRN-R, LFN, or equivalent
Logic Input Current
1.5 A
Logic Input Voltage
22 to 27V DC
Peak Current (Amps for 2 sec)
6 (1?), 6 (3?) A
Peak Current (Amps for 500 ms)
6 (1?), 6 (3?) A
Power Ratings (kVA at 115V)
0.35 (1?), 0.6 (3?) KVA
Power Ratings (kVA at 230V)
0.8 (1?), 1.2 (3?) KVA
Recommended EMI Line Filter
SF7, 3H Series*, FN258-7/07
Soft Start (Max Surge Current)
2.5 A max
Voltage (VAC, Nominal ~10%)
110 to 230V