HZ171A607 by Danaher

Rated 4.9 stars (12 reviews)

Get a Quote for HZ171A607

Request a quote or call us now at 1-888-551-3082!

In-Stock, Ships 3-5 Days

We respect your privacy. Your information is safe and will never be shared.

Secure Online
Checkout

Free Ground
Shipping

One Year
Warranty

The HZ171A607 is an electromechanical preset counter supplied by Danaher within the Timers and Controllers series. Used in industrial automation panels, it drives a mechanical index shaft to start or stop downstream equipment once a preset tally is reached. By energizing an internal stepping motor and clutch, the product advances through counts and opens or closes an external relay when the preset is met. Its front dial provides a quick way to establish a target without programming software.

The counter operates from a single-phase input of 120 VAC. Inside, the stepping motor completes each increment within 40 ms, while the clutch fully engages after 50 ms. At steady state, the mechanism can register up to 500 counts/min with a count accuracy of 100%. This accuracy supports a one-to-one relationship between accepted input pulses and mechanical increments. The output relay can switch resistive loads up to 10 A at the same mains voltage, permitting direct connection to small heaters, solenoids, or contactors. During operation, the front-bezel dial lock prevents vibration or incidental contact from changing the preset, and the wheel offers a maximum count setting of twelve.

After a batch is completed, the reset solenoid clears the wheel within 500 ms, and the drive remains idle for 80 ms before the next on-pulse arrives. While the mechanism is held, the clutch imposes a 10.5 VA burden, and motor startup draws 26 VA. The electrical burden differs by operating state because the clutch and motor are energized at different points in the cycle. The assembly withstands ambient temperatures up to 60 °C. The housing measures 96.82 mm wide and 107.95 mm high, with a depth of 146.05 mm. The width and height determine front-panel spacing, while the depth establishes the required clearance behind the enclosure door.

Technical Specifications

Clutch Holding Burden
10.5 VA

Clutch Pull-in Time
50 ms

Count Accuracy
100%

Dial Lock
Included

Maximum Count Setting
12

Maximum Counting Speed
500 counts/min

Maximum Operating Temperature
60 °C

Motor Off Time
80 ms

Motor On Time
40 ms

Output Current At 120 Vac
10 A

Overall Depth
146.05 mm

Overall Height
107.95 mm

Overall Width
96.82 mm

Reset Time At Maximum Setting
500 ms

Stepping Motor Inrush Burden
26 VA

Supply Voltage
120 VAC

Click here for product datasheet

Contact Us

1620 Old Apex Road, Cary, NC 27513, USA

Toll Free: 1-888-551-3082

International: 1-919-443-0207

Fax: 1-919-867-6204

Email: sales@wakeindustrial.com

Shipping Options

DHLFedExUPSFreight

Payment Methods

American ExpressMasterCardVisaWire Transfer

Need Assistance?

Our team is here to help you find the right part for your needs.

Worldwide Shipping with FedEx and UPS.

We accept all major credit cards

1 year Automation Factory warranty on ALL products