Continuous Output Current
~10 A @ 80 V
Current Mode Bandwidth
3 kHz
Current Monitor Output
~6 V at peak current
Differential Amplifier Gain
1:1 V/V
LED Indicators
Normal, Power OK, Fault
Load Inductance Range
200 µH to 40 mH
Logic Input Threshold
2.5 V
Logic Input Voltage Range
0 to +24 V
Logic Outputs
Fault/Normal, TTL-level
Max Reference Voltage
20 V
Output Voltage Formula
Vout = 0.97·HV - 0.2·Io
Overtemperature Shutdown
70 °C
Peak Output Current
~20 A @ 80 V
PWM Switching Frequency
25 kHz
Reference Input Impedance
100 kΩ
Reference Input Type
Differential
Short-circuit Detection
Yes
Voltage-feedback Mode Bandwidth
200 Hz