VT-HNC100-1-30/S-I-30/000 by Bosch Rexroth Indramat
Get a Quote for VT-HNC100-1-30/S-I-30/000
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
Technical Specifications
Analog Output Resolution
1.25 mV
Analog Voltage Input Non-linearity (±10 V)
35 mV
Analog Voltage Input Non-linearity (±9.5 V)
15 mV
CANopen Interface
Supported
Digital Position Transducer Interface
Incremental (TTL), SSI
Incremental Input Current HIGH
+0.8 mA at 5 V
Incremental Input Current LOW
-0.8 mA at 0 V
Incremental Input Voltage Levels
LOW 0–1 V; HIGH 2.8–5.5 V
INTERBUS-S Interface
Supported
Load Resistance for Current Outputs
500 Ω
Max Frequency for Incremental Transducer
250 kHz
Operating Voltage
18–36 VDC
Output Current non-normalized
±23 mA
Output Current normalized
4–20 mA
Position Transducer Supply
+5 VDC ±5%, 200 mA max
PROFIBUS DP Interface
max 12 MBaud
Serial Interface
RS232, 9.6 kBaud
SSI Data Width
up to 28 bits (Gray Code)
Voltage Output Range
-10–+10 V (max ±10.7 V)