VT 3000-3X-ES-E61-A204-U177 by Bosch Rexroth Indramat
Get a Quote for VT 3000-3X-ES-E61-A204-U177
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
The VT 3000-3X-ES-E61-A204-U177 is an analog amplifier card produced by Bosch Rexroth Indramat for the VT 3000 Analog Amplifiers series. Installed in hydraulic power units, it converts low-level command voltages into a pulse-modulated coil current that positions proportional valves. By occupying a single Eurocard slot, the module gives machine builders a compact way to adjust pressure or flow with electronic precision while retaining the reliability expected in industrial automation environments. The card interfaces with standard control racks and is often used in presses, die-casting cells, and mobile test stands that need repeatable motion control.
It mates with a 32-pin Eurocard connector and operates from a regulated 24 VDC ±10% supply, drawing up to 30 W during simultaneous valve actuation and relay switching. The main control channel accepts a bipolar ±9 V signal; an auxiliary ±6 V input and a differential 10 V port allow summing or override functions. Four trim potentiometers permit field adjustment, and four front-panel LEDs show power, enable, error, and limit states. Six internal relays handle mode selection and external interlocks. The power stage can deliver an instantaneous 800 mA to the solenoid and never falls below a 20 mA bias, so valve spool overlap is crossed smoothly.
The output path is safeguarded by a 2.5 A fuse housed in a standard 5 mm × 20 mm carrier. To reach rated dynamics, the connected solenoid must present no more than 19.5 ? of coil resistance, and current is applied through a PWM generator that keeps transistor temperatures within limits. The signal conditioner demands at least 500 ? of source impedance to preserve gain accuracy when long cables are used. This combination of protection, modulation method, and input constraint helps keep the valve response linear across the full stroke.
Technical Specifications
Additional Command Input
±6 V
Card Format
32-pin Eurocard
Contact Relay Count
6
Control Input Voltage
±9 V
Differential Input
10 V
Fuse Rating
2.5 A
Fuse Size
5 mm x 20 mm
Input Potentiometer Count
4
Led Indicator Count
4
Max Coil Resistance
19.5 ?
Maximum Output Current
800 mA
Minimum Bias Current
20 mA
Minimum Input Load
500 ?
Output Modulation
PWM
Power Consumption
30 W
Power Supply Voltage
24 VDC ±10%