Technical Specifications
Biasing current adjustment
10–300 mA (potentiometer R130)
Card dimensions
100 × 160 mm (Euro-card, DIN 41494)
Clock frequency
100 or 200 Hz ±10% (jumper S2)
Command input voltage
0–9 V (ref. M0)
Current consumption
<1 A
Differential input voltage
0–10 V, 100 kΩ input resistance
Front panel height
3 HE (128.4 mm)
Front panel width
4 TE (20.32 mm)
Fuse rating
2.5 A T (slow-blow)
Operating voltage
24 VDC (+40%/-5%); range 22–35 V
Output current range
0–800 mA (1 mV/mA)
Permissible operating temperature
0–50 °C
Power consumption
<25 VA
Ramp time adjustment
30 ms to 1 or 5 s (jumper S1)
Type of connection
32-pin male connector, DIN 41612 form D
Warranty
1 year
Weight
0.1 kg