IE2022-0000 by Beckhoff
Get a Quote for IE2022-0000
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
The IE2022-0000 extension box is produced by Beckhoff for the IE Extension Box Units series. It serves as a decentralized output module that places switching power next to actuators, reducing control cabinet wiring in industrial automation cells. The enclosure accepts 24 V field power and relays it to connected loads under EtherCAT supervision when combined with a suitable master. Because the enclosure is IP-rated for machine-side installation, it can be fastened to steel framing, conveyors, or tooling wherever compact digital outputs are required. This arrangement allows solenoids, lamps, and contactors to be driven without long home-run cables.
The unit operates from a nominal supply of 24 VDC. It provides 8 digital outputs, each rated at 2.0 A per channel, and the total load must not exceed 4 A. Within the controller's memory map, it occupies a single 8-bit output image, ensuring byte-aligned access. Electrical terminations use an M12 screw-in connector that seals against oil and dust on the shop floor. There is no channel or interchannel isolation, so all outputs share a common reference, while the control and fieldbus circuits remain galvanically separated. A short-circuit threshold of 4.0 A disables a faulted path to protect upstream conductors. Control and fieldbus isolation helps maintain communication integrity during load transients. The variable installation position allows the housing to be mounted flat or on its edge without derating.
Each output stage draws 30 mA per channel for its internal electronics, and the auxiliary sensor rail can supply up to 0.5 A per channel for proximity switches or encoders. Downstream expansion is supported by one 4-pin M8 socket, while upstream field power enters through one 4-pin M8 connector. These feeder and daisy-chain connections allow additional IE boxes to be cascaded along the machine. The compact connections also help route field power through confined areas where larger connector assemblies would interfere with nearby equipment. Connected devices share the available supply limits, so the combined load must remain within the permitted current for the module and its individual channels.
Technical Specifications
Auxiliary Power Current
30 mA per channel
Channel Isolation
No
Control/fieldbus Isolation
Yes
Current Consumption
30 mA per channel
Current Consumption (Us)
25 mA
Downstream Connection
1×M8 female, 4-pin, A-coded
Downstream Port
1 x M8 socket, 4-pin
Feed Connection
1×M8 male, 4-pin, A-coded
Installation Position
Variable
Interchannel Isolation
No
Load Types
Ohmic, inductive, lamp
Max. Output Current per Channel
2 A
Nominal Output Voltage
24 V DC (-15%/+20%)
Nominal Voltage
24 VDC
Number of Outputs
8
Operating Temperature
0...55°C
Output Connection
M12 screw-in
Output Connections
M12, screw type
Output Current
2.0 A per channel
Power Feed
1 x M8 connector, 4-pin
Process Image
8 bits output
Protection Rating
IP65/IP66/IP67
Sensor Supply Current
0.5 A per channel
Shock Resistance
EN 60068-2-27
Short Circuit Current
4.0 A
Short-Circuit Proof
Individually short-circuit proof
Storage Temperature
-25...+85°C
Total Max. Output Current
4 A
Total Output Current
4 A
Vibration Resistance
EN 60068-2-6
Contact Us
1620 Old Apex Road, Cary, NC 27513, USA
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Fax: 1-919-867-6204