ELX3204-0090 by Beckhoff
Get a Quote for ELX3204-0090
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
The ELX3204-0090 temperature input terminal is produced by Beckhoff for the EL EtherCAT Terminals series. It mounts on a DIN rail and forwards resistance temperature detector data to the EtherCAT fieldbus so PLCs can monitor thermal conditions. The module provides intrinsically safe measurement channels that allow direct connection of approved RTDs in process automation environments where hazardous-area wiring must remain below the energy limits established for Ex zones.
It offers 4 differential inputs that use a 2-wire technique to read Pt100 sensors by default while also accepting Pt200, Pt500, Pt1000, Ni100, Ni120, and Ni1000 elements. Each channel appears in the process image as one of four 32-bit RTD values and samples at a default conversion time of 270 ms. The internal analog-to-digital converter resolves temperature changes down to 0.1 °C/digit, and its analog front end filters signals up to 1 kHz to suppress unwanted noise. Linearity and component tolerances keep the total measurement error below ±0.3% FSV, with less than 1 mA of sensor current and an internal resistance of at least 10 k?. The intrinsic safety parameters include a field-interface voltage of 4.94 V, a current limit of 12 mA, and a maximum power release of 15 mW.
System integration is handled through the EtherCAT E-bus, which supplies 5 VDC to the terminal logic. The galvanically isolated power contacts provide 24 VDC Ex for downstream modules while preserving the energy restrictions of the hazardous segment. The terminal has a fixed cyclic redundancy check value of 8. TwinSAFE SC support is available for four channels that deliver four INT16 values, and configurable TSC settings are available at index 8040 for functional safety diagnostics. The housing measures 15 × 100 × 70 mm and has an IP20 protection rating for cabinet-mounted installations.
Technical Specifications
Connection Method
2-wire
Connector Type
Standard connector
Control
Limit switches
Default Conversion Time
270 ms
Default Sensor Type
Pt100
Dimensions
15 x 100 x 70 mm
Duty Cycle
20%
E-bus Supply
5 VDC
E-bus Voltage
5 VDC
Field Interface Io
12 mA
Field Interface Po
15 mW
Field Interface Uo
4.94 V
Fixed Crc Count
8
Housing Material
Aluminum
Input Filter Limit
1 kHz
Input Type
Differential
Input Voltage
24 VDC
Internal Resistance
>=10 k?
Maximum Load
500 N
Measuring Current
<1 mA
Measuring Error
<±0.3% FSV
Mounting Type
Front and rear clevis
Number Of Inputs
4
Operating Temperature
-10°C to +50°C
Power Contact Supply
24 VDC Ex
Power Contact Voltage
24 VDC Ex
Process Image Width
4 x 32-bit RTD input
Protection Class
IP20
Resolution
0.1°C/digit
Stroke Length
90 mm
Supported Sensors
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000
Tsc Settings Index
8040
Twinsafe Sc Channels
4
Twinsafe Sc Values
4 x INT16
Type
Linear Actuator
Weight
1.2 kg