The EK1818 EtherCAT coupler is manufactured by Beckhoff and offered within the EK EtherCAT Couplers series. As a network interface, it terminates an EtherCAT segment and translates high-speed fieldbus telegrams to the internal E-bus used by the attached terminal blocks. The unit allows discrete inputs and outputs to be mounted directly on the machine while maintaining synchronous data exchange with the PLC or IPC that runs the control program. It serves as a gateway between centralized logic and decentralized I/O devices in automated equipment.
The EtherCAT side transmits at a line rate of 100 MBaud and connects to the machine network through two RJ45 sockets that support automatic port switching. With a telegram forwarding delay of only 1 µs, the coupler supports time-critical applications that rely on distributed clocks. It accepts up to 8 digital input signals and provides 4 transistor outputs, allowing compact sensor clusters and valve islands to reside beside the controller. Transient noise on the input channels is attenuated by a 3 ms filter, and each output channel can absorb 150 mJ of inductive braking energy when a load is de-energized. The segment length may extend to 100 m between nodes using standard Cat-5e cabling.
The terminal bus is powered by an internal supply that delivers 1000 mA along the E-bus, allowing multiple electronic terminals to be stacked without extra feeders. Field power for the outputs is drawn from a nominal 24 VDC source, and each channel can switch loads up to 0.5 A while limiting fault currents to less than 2 A during short circuits. Typical input circuits draw only 3 mA from the sensor supply, minimizing voltage drop over long wiring runs. The housing meets the IP20 protection class, so the coupler is intended for installation inside control panels or closed machine enclosures.
Technical Specifications
Baud Rate
100 MBaud
Breaking Energy
150 mJ/channel
Bus Connection
2 x RJ45
Delay
1 µs
Digital Inputs
8
Digital Outputs
4
E-bus Power Supply
1000 mA
Input Filter
3 ms
Max Cable Length
100 m
Nominal Input Voltage
24 VDC
Output Current per Channel
0.5 A
Protection Class
IP20
Typical Input Current
3 mA
Typical Short-circuit Current
< 2 A