EK1100 by Beckhoff
Get a Quote for EK1100
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
The EK1100 is an EtherCAT bus coupler produced by Beckhoff in the EK EtherCAT Couplers series. Mounted at the head of a row of I/O terminals, it translates 100 Mbps fieldbus signals to the internal E-bus so that every terminal receives synchronized process data. The device supplies logic power and passes power through its contacts, allowing compact terminal stations to be installed on a DIN rail. By acting as the communication bridge between an EtherCAT master and modular I/O terminals, it forms the entry point for sensors and actuators in distributed control systems.
The coupler draws 24 V DC from a two-pin feed to energize its processor and Ethernet physical layer. Network access is provided by two RJ45 sockets that permit a line or branch topology without additional switches. Frames are forwarded at 100 MBaud, and internal processing contributes a typical latency of only 1 µs, keeping motion and high-speed sampling cycles closely synchronized. Address mapping of up to 4.2 GB allows thousands of bit, byte, or word channels to be organized in one contiguous EtherCAT image, so even large terminal banks remain within a single logical station. Current consumption on the upstream 24 V line is 70 mA plus one-quarter of the total E-bus draw, which simplifies power supply sizing in panel designs.
The enclosure meets the IP20 protection rating, so the wiring and coupler must be installed inside a protective cabinet. Segment cabling may extend up to 100 m between couplers, aligning with the Cat 5e requirements of Ethernet 100BASE-TX physical media. Through the E-bus backplane, the unit can supply 5 V at 2 A to terminal electronics, while separate power contacts carry 24 V DC at 10 A to field devices without additional feeds. Communication conforms to the EtherCAT Device Protocol, supporting deterministic data exchange between the master and connected terminals. Hot Connect is not supported, so terminal configuration changes must be performed while the controller is not running.
Technical Specifications
Addressable Io Points
4.2 GB
Bus Connection
2 x RJ45
Current Consumption
70 mA + (Sum E-bus current/4)
Data Rate
100 MBaud
Delay
1 µs typ.
Hotconnect
No
Max Cable Length
100 m
Max E-bus Output
5 V, 2 A
Network Standard
Ethernet 100BASE-TX
Power contacts
24 VDC, 10 A
Power Supply
24 VDC
Protection Class
IP20
Protocol
EtherCAT Device Protocol
Contact Us
1620 Old Apex Road, Cary, NC 27513, USA
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Fax: 1-919-867-6204
Email: sales@wakeindustrial.com