BK2000 by Beckhoff
Get a Quote for BK2000
Request a quote or call us now at 1-888-551-3082!
We respect your privacy. Your information is safe and will never be shared.
Secure Online
Checkout
Free Ground
Shipping
One Year
Warranty
The BK2000 is a bus coupler manufactured by Beckhoff for the BK Bus Couplers series. It links a block of Beckhoff K-bus terminals to a higher-level automation network and translates terminal data into fieldbus frames. The device also supplies operating power to the attached I/O stations, supporting compact remote I/O installations that can be expanded as machine requirements change.
The coupler communicates over the Lightbus protocol at a data transfer rate of 2.5 Mbit/s, providing the cyclic throughput used for communication with the controller. Its internal supply rail accepts 24 VDC and energizes the coupler electronics and downstream terminals without an auxiliary supply. Up to 64 standard bus terminals can be connected directly to the coupler. Capacity can be expanded to 255 channels when a K-bus extension module is installed, allowing a single node to accommodate additional sensors, actuators, and special-function terminals. The fieldbus interface and K-bus operate independently, so fieldbus communication and terminal data exchange can be processed without interfering with each other. The enclosure is intended for installation in a control cabinet that provides suitable protection from water, debris, and unintended contact.
The coupler snaps onto a 35 mm rail compliant with EN 60715, permitting straightforward installation and removal when panel layouts change. Its variable installation position allows the unit to be mounted horizontally or vertically without disrupting convection cooling. The housing has an IP20 protection rating, shielding live parts from accidental finger contact while allowing air to circulate around the enclosure. Storage and transportation are permitted within a temperature range of -25 °C to +85 °C, allowing the device to remain in unconditioned storage areas when it is not operating. Adequate spacing around the housing helps preserve airflow and provides access to the terminals and network connections during installation.
Technical Specifications
Analog Peripheral Signals
128 inputs and outputs
Baud Rates
2.5 MBaud
Configuration Interface
Available for KS2000
Current Load Power Contact
10 A
Data Transfer Rate
2.5 Mbit/s
Digital Peripheral Signals
256 inputs and outputs
Fieldbus Type
Lightbus
Foreign Object Protection
Less than 12 mm
Input Current (maximum)
900 mA
Input Current (typical)
105 mA
Installation Position
Variable
Max Bus Terminals
64
Max With K-bus Extension
255
Mounting Rail
35 mm per EN 60715
Number Of Bus Terminals
64
Operating Temperature
0 degrees C to +55 degrees C
Output Current (k-bus)
1.75 A max
Peripheral Bytes
512 input and 512 output bytes
Protection Class
IP20
Storage Temperature
-25 °C to +85 °C
Supply Isolation
500 V (K-bus / supply voltage)
Supply Voltage
24 VDC
Voltage Power Contact
24 V DC / AC
Voltage Supply
24 V, +/- 10%
Water Protection
No protection
Weight
approx. 150 g
Contact Us
1620 Old Apex Road, Cary, NC 27513, USA
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Fax: 1-919-867-6204
Email: sales@wakeindustrial.com
Need Assistance?
Our team is here to help you find the right part for your needs.







